Tips
Pop
cancel
confirm
您的浏览器不支持视频播放
❮
❯
Video
Image
Product info
Product name:
Transport Infant Incubator
Product code:
CCI-TI2000
Packaging Specifications
Outer Packaging Size:
1.09 × 0.65 × 0.7 m
Gross Weight:
88 kg
Net Weight:
65 kg
Volume:
0.5
Outer Packaging Size:
1.38 × 0.61 × 0.37 m
Gross Weight:
53 kg
Net Weight:
33 kg
Volume:
0.31
Description
Product Introduction
Control Modes
: Two temperature control modes: Air mode and Baby mode, controlled by a microcomputer.
Power Options
: Uses AC power and DC power alternatively; supports DC 12 V or DC 24 V power on the ambulance.
Display
: Set temperature, air temperature, baby temperature, and internal battery voltage can be displayed separately.
Alarms
: Failure alarm indication.
Over‑Temperature Function
: Can be equipped with > 37 °C temperature set function.
Hood
: Double‑wall acrylic glass hood with a side door, allowing the bassinet to be pulled out.
Humidity
: Natural air flow humidity.
Height Adjustment
: The height of the whole unit is adjustable.
Systems
: Oxygen supply system.
Observation
: Observation lamp.
Basic Configuration
Main body (including the hood, controller, bassinet, internal battery, and observation lamp)
Oxygen cylinders
Oxygen supply system
Skin temperature sensor
I.V. Pole
Mattress
Adjustable stand
Main Parameters
AC power requirement
: AC 220‑230 V 50 Hz or AC 110‑120 V 50‑60 Hz, 400 VA
DC power requirement
: DC 12 V 10 A or DC 24 V 6 A
Mode of control
: Air mode and baby mode controlled by microcomputer
Air temperature control range
: 25 °C–37 °C (Override mode 37–38 °C)
Baby temperature control range
: 34 °C–37 °C (Override mode 37–37.5 °C)
Skin temperature sensor accuracy
: ± 0.2 °C
Temperature difference between incubator temperature and average incubator temperature (under steady temperature condition)
: ≤ 1.0 °C
Temperature uniformity
: ≤ 1.5 °C (mattress is on the horizontal position)
Noise inside hood
: ≤ 52 dB(A)
Failure alarm
: Over‑temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, and so on.
Battery continuous working time
: 90 min (Set temperature is 36 °C—Ambient temperature is 15 °C)
Environmental Conditions
Operating range
: 10 °C ~ 30 °C (Set temperature should be 3 °C higher than the environment temperature)
Ambient air movement rate
: > 0.3 m/s, < 1.0 m/s
Product Packaging
Package
: Each unit is packed into two cartons.
Main body dimensions
: 1090 mm × 655 mm × 760 mm
Cabinet dimensions
: 1380 mm × 610 mm × 400 mm
Main body gross weight
: 80 kg
Cabinet gross weight
: 53 kg
User review