Audiometer
High Quality Audiometric Instruments
The CCSVQA700P is a clinical audiometer that provides all necessary air and bone conduction test capabilities with masking. It offers a range of test features such as Pure-tone, Speech audiometry and additional Hughson-Westlake auto test.
Operation is simple and intuitive. The buttons, indicator lights and screen clearly display the device’s current settings including sound level, frequency, transducer, signal type, audiogram, channel etc. The ergonomic design is exceptional with a high resolution 7-inch color display that presents crystal clear images for easy read audiograms. The device has various user-defined settings which enable you to acclimate quickly without losing efficiency or speed.
The device supports standalone mode to monitor test results, data storage and printing or connects to PCs running management software for more functions such as data sync, data export, diagnosis and printing template modification.
The CCSVQA700P clinical audiometer is designed for the diagnosis of hearing loss.
Audiometer Standards: Complies Type 2 clinical audiometer design standards
Functions: HL, MCL, UCL, Speech support external CD, live voice via microphone or internal word list, Hughson-Westlake Auto test, Suprathreshold tests including Stenger, ABLB, SISI
Output Type: Air, Bone, Free Field, Insert earphone
Stimulus: Pure Tone 125-8000Hz, Warble Tone 5Hz sine ±5% modulation, Pulse Tone Multiple pulses 250ms on, 250ms off, Single or Continuous press sound mode
Masking Signal: Narrow band noise, Speech noise, Synchronous masking: Locks channel 12 attenuator to channel 1 attenuator, White noise
Frequency Range: 125Hz to 8kHz, 125Hz, 250Hz, 500Hz, 750Hz, 1kHz, 1.5kHz, 2kHz, 3kHz, 4kHz, 6kHz, 8kHz or 4kHz better than 0.1%
Intensity: AC: -10 to 120 dB HL, BC: -10 to 80 dB HL, Audiometer intensity steps 1,2 or 5dB, Extended range function: If not activated, the Air Conduction output will be limited to 20 dB below maximum output
Calculation Method: Tone Test: PTA(WHO or ANSI standards), Speech scoring: SRT,WRS
Print: Design print page information, Direct printout by USB connection to printer
Testing Setting: Offer sedative configuration options and support saving
Calibration Accuracy: ±0.1dB, Calibration information and instructions is located in the user manual
Signal Indicator(VU): Time weighting: 300ms, Dynamic range: 23dB, Rectifier characteristics: RMS, Selectable input and output, adjustable by the individual potentiometer (rear panel)
External Signal(CD): 0.020 to 0.2 Vrms
Patient communication: Patient Response Switch(one push button), Talk Forward(via Machine MIC), Talk Back(via patient MIC)
Display: 7 inch (1024×600) color display
Internal storage: Up to 100,000 audiograms. Capacity of PC depends on hard disk.
Operating mode: Standalone, PC-based(via Computer Management and Diagnostic Software)
Hospital Database: HL7, SQL, FTP interface or Local export PDF/PNG/XML/JSON format
Data Interaction and Peripherals: 1 x USB B for PC connection, 3 x USB A for printer, keyboard or mouse.
Weight: 2.1 kg
Power supply: 100 - 240VAC, 50/60Hz, 12VDC-max 1A
Warm-up time: Approx. 1 minute
Dimensions (L×W×H): 343×270×92mm