Product info

Packaging Specifications

Core Parameters

Description



Double Channel Micro Syringe Pump

Model: CC24093001


Features


  • Precision: ≤+3%
  • IP Level: IPX1
  • Drug library: ≥210
  • 4.3‑inch color touch screen; combined humanized function buttons and touchscreen for easier and faster operation
  • Pressure Monitoring: 4 editable pressure levels to guarantee injection accuracy
  • Automatic calibration
  • Dual‑CPU design for safer operation
  • System self‑test on every power‑on, covering alarm volume, pressure, air‑bubble and other items
  • History log: store up to 7000 records for medical staff to check syringe‑related data conveniently

Technical Specifications

ItemParameters
Applicable Syringe5ml,10ml,20ml,30ml,50ml
Syringe ModeRate mode, Time mode
Injection Speed50ml syringe:0.10ml/h~1800.00ml/h(0.01ml/h step)30ml syringe:0.10ml/h~900.00ml/h(0.01ml/h step)20ml syringe:0.10ml/h~600.00ml/h(0.01ml/h step)10ml syringe:0.10ml/h~300.00ml/h(0.01ml/h step)5ml syringe:0.10ml/h~150.00ml/h(0.01ml/h step)
Fast forward speed30ml syringe:900.00ml/h20ml syringe:600.00ml/h10ml syringe:300.00ml/h5ml syringe:150.00ml/h
Flow rate accuracyWithin ±3%
Mechanical accuracy of the pumpWithin ±3%
Preset injection volume0.10~9999.99ml
Power supplyAC ~220V,50Hz; Built‑in 11.1V rechargeable lithium‑ion battery pack, capacity≥3500mAh; can work over 4 hours at 5ml/h after 10‑hour charging
Power supply methodMains (AC) power supply and built‑in rechargeable battery power supply
KVO rate0.10~5.00ml/h(Increment 0.01ml/h)
Fuse specificationsF1AL/250V, two fuses installed inside pump
Equipment classificationClass I, internal power supply, Bf‑type continuous‑operation equipment
Power40VA
Dimensions286.7mm(L)×110.8mm(W)×199mm(H)
Weight3.2Kg
Operating environmentAmbient temperature:+5°C~+40°C; Relative humidity:20%~90%; Atmospheric pressure:86.0KPa~106.0KPa
Transportation & storageAmbient temperature:-30℃~+55℃; Relative humidity:≤95%; Atmospheric pressure:50.0KPa~106.0KPa
Blockage alarm threshold pressureP1:225mmHg‑375mmHg(30kPa‑50kPa)P2:375mmHg‑525mmHg(50kPa‑70kPa)P3:525mmHg‑675mmHg(70kPa‑90kPa)P4:675mmHg‑825mmHg(90kPa‑110kPa)
Alarm typesNo‑operation warning, Low‑battery warning, Near‑completion warning, Near‑empty warning, KVO completion alarm, Injection completion alarm
Auditory alarm sound pressure45dB~85dB