  • Compact and portable, easy to use.
  • With Integrative SpO₂ Probe.
  • Double working modes, monitoring function and 24 hours ambulatory NIBP measurement function can be flexibly set.
  • Long time monitoring BP and SpO₂, displaying value of BP, SpO₂ and PR.
  • NIBP and SpO₂ data Record for large capacity.
  • With friendly user interface, the user can see list menu and review measurement results.
  • The device can display low power information, alarm information, error information and time information richly.
  • Parameter alarms function is optional.
  • Patient information can be flexibly set.
  • Case management function. PC software can achieve data review, analysis measurement results, seeing trend, printing reports and other functions.
  • Data can be transmitted between device and computer, such as upload patient information, download measurement data.
  • English and Chinese menu.


Function of master device software:


  • Set patient information through PC software.
  • Up to 1000 patients cases can be edited and supervised.
  • The time segment of dealing with the patient’s NIBP data is 48 hours.
  • Connect the device by USB interface.
  • Can upload patient information data collection project and download collection data.
  • Can display scoop‑shape trend graph, filing‑type trend graph, histogram, pie chart, correlation line graph.
  • Can edit every piece of data, and add annotation to it.
  • Can edit basic information, doctor’s advice information, NIBP and SpO₂ status instruction, current medicine‑taken information, etc.
  • Support print preview, print the report.


Physical characteristic


  • Dimension: 128mm(L) × 69mm(W) × 36mm(H)
  • Weight: <350g (including batteries)


Performance

NIBP :


  • Measurement Method: Oscillometry
  • Measurement Mode: The upper arm measure
  • Measuring range:
    SYS 40mmHg ~ 270mmHg
    MAP 20mmHg ~ 235mmHg
    DIA 10mmHg ~ 215mmHg
  • Automatic Measurement Interval: 5,10,15,20,30,45,60,90,120 minutes
  • Resolution: 1mmHg
  • Accuracy: ±3mmHg
  • Increasing pressure mode: force pump increases pressure automatically
  • Reducing pressure mode: self‑motion ladder reducing pressure mode
  • Alarm parameter: SYS / DIA


  • SpO₂


  • Measuring range: 0% ~ 100%
  • Resolution:1%
  • Accuracy: 70‑100%, ±2%, below 70% unspecified
  • Error in Weak Filling Condition:SpO₂ and pulse rate can be shown correctly when pulse‑filling ratio is 0.4%. SpO₂ error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
  • Resistance to surrounding light The deviation between the value measured in the condition of man‑made light or indoor natural light and that of darkroom is less than ±1%.
  • Pulse Rate:


  • Measuring range:30bpm‑250bpm
  • Resolution:1bpm
  • Accuracy: ±2 bpm or ±2% (select larger)


  • Display:


  • 2.4" TFT colour LCD


  • Safety:


  • Power: DC 3V (Two "AA",1.5V Alkali Battery )