Flow Cytometry(FCM)+Tri‑angle laser scatter+Chemical staining method for WBC differentiation
Impedance method for RBC and PLT test
Cyanide free colorimetry for HGB test
Parameters: WBC,Neu#,Lym#,Mon#,Eos#,Bas#,Neu%,Lym%,Mon%,Eos%,Bas%,RBC,HGB,HCT, MCV,MCH,MCHC,RDW‑CV,RDW‑SD,PLT,MPV,PDW,PCT,P‑LCC,P‑LCR,ALY#,LIC#, ALY%,LIC%,four scattergrams,two histograms
Sample Mode: Whole blood,capillary whole blood and pre‑diluted mode
Throughput: 60 samples/hour
Detecting Channels: Dual channels
Sample Volume: CBC 20uL,CBC+DIFF 20uL,pre‑diluted mode 20uL
Calibration Methods: Manual calibration,calibrator calibration
Display: 10.4‑inch full‑color touchscreen
Dimension: (WHD)325465470mm³
Net Weight: 29Kg
Languages: English,Spanish,Customized Language
Interface: 4 USB ports,bidirectional LIS function,LAN interface supports HL7 protocol
Optional Accessories: External barcode scanner,printer,mouse,keyboard
Supporting Reagents: Diluent,Hemolytic agent,Hemolytic agent,Probe cleanser
10.4‑inch full‑color touchscreen
User friendly operation software
4USB ports for data transmitting and external printer connection
No barrier around the needle
Suitable for either left or right hand
4 reagents in total 2 years shelf life
Small and Convenient,Easy to Detect
The analyzer is compact and convenient for operation and testing in the laboratory.The open sample loading design allows for instantly initial screening in outpatient and emergency department.The built‑in design of the reagent compartment door is adopted to save the space of the laboratory.
Coulter's principle was used to detect the number and volume distribution of red blood cells(RBC)and platelets(PLT).A separate BASO channel is adopted with optical counting to make the differentiation more precise.
Open System Available
Small and Convenient, Easy to Detect
The analyzer is compact and convenient for operation and testing in the laboratory. The open sample loading design allows for instantly initial screening in outpatient and emergency department. The built‑in design of the reagent compartment door is adopted to save the space of the laboratory.
Coulter's principle was used to detect the number and volume distribution of red blood cells(RBC)and platelets(PLT). A separate BASO channel is adopted with optical counting to make the differentiation more precise.
Flow Cytometry(FCM)+Tri‑angle laser scatter+Chemical staining method for WBC differentiation
Impedance method for RBC and PLT test
Cyanide free colorimetry for HGB test