- Description
Specifications
Type:
Fully Automated
Sample Tests/Hour:
200tests
Size:
Tabletop Type, Floor Standing Type
60 reagent positions 81 reaction positions Auto washing
Good economic choice to replace semi-auto
Technical Specifications
Performance
Type: Discrete Automatic, Random Access
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 200tests/hour (without I SE),up to 320tests/hour
Test Method: End-point, Fixed-time, kinetic
Test Sequence: Run tests in strict accordance with sample sequence,Insert emergency at any time
Optical System
Light source: Halogen-tungsten lamp, 12V/20W
More than 2000hrs service time
Spectrometric method: After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Detector: Photodiode array
Absorption range: 0-4.0Abs
Optical system: Integrated full closed optical system
Reaction system
Reaction tray: 81 positions
Reaction volume: Mini 150μl
Sample system
Sample tray: 60 positions
Sample volume: 2-100μl , 0.1μl by step
Online sample: 60 samples/ batch, unlimited batch input
Reagent System
Reaction tray: 60 positions, open system
Reagent volume: 20-500μl, 1μl by step
Reagent bottle: Bottles with 15ml and 30ml are available, dead volume﹤0.5ml
Working Conditions
Water consumption: Less than 5L/hour
Power supply: AC 220 ±22V 50HZ ±1HZ
Power: Max 200VA
Ambient temperature: 15°C-30°C
Dimension(L*W*H): 79x59x108cm
Net Weight: 90KGS
Temperature Control System
Heating mode: Solid constant temperature closed direct heating
Heating time: Less than 3minutes
Reaction temperature: 37±0.2°C
Temperature fluctuation: ± 0.1°C
Refrigeration system: 24 hours cooling for reagent tray, temperature: 4-12°C
Calibration and QC
Calibration mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
Automatically check calibration curve and fitting the best calibration curve
QC type: Multi-type
QC rules: Multi-rule; default: Westguard
Status monitoring: Real -time monitor the sample tray, reagent tray, reaction tray; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection and judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reagent blank absorbance judgment
Operation and Print
Operation system: Windows XP or Windows 7 Home Basic
Database: SQL Server
Data storage: Automatic storage and backup, permanently preserve all kinds of data
Print content: Print content can be customized
Print format: Provide a variety of print format
Shipping Information:
G.W: 120kg
Packing Size: 0.9m,0.7m,1.2m
Unit:
Special:
Name:
Email:
Whatsapp/Tel:
Message: