12.1 Touch Screen ICU System Ventilator 12.1 Touch Screen ICU System Ventilator12.1 Touch Screen ICU System Ventilator12.1 Touch Screen ICU System Ventilator
Cheap, Various, Quality, Fast Shipping
Your position: Home > Product By Name > Ventilator machine

12.1 Touch Screen ICU System Ventilator

1. Microprocessor controlled, Pneumatically driven electronically controlled 2. 12.1" TFT touch screen, user friendly interface 3. Built-in medical air compressor, built-in backup battery up to 3hrs 4. LCD display ventilation parameters, preset paramet
Item Code: CCV-3010
Sold: 10
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Units
  • Description
Specifications
Type: Trolley
Main Features:
 
1. Microprocessor controlled, Pneumatically driven 
electronically controlled
2. 12.1" TFT touch screen, user friendly interface
3. Built-in medical air compressor, built-in backup
battery up to 3hrs
4. LCD display ventilation parameters, preset
parameters alarm indication and breathing waveform
5. Applied for adult and child
6. CE marked
 
Air compressor technique info
7. Output pressure: 0.4MPa ±0.1MPa
8. Noise ≤50dB
9. Power: AC 220V ± 10%, 50Hz ± 2%
 
Main Specification
Ventilation Mode
IPPV, SIGH, A/C (SIPPV), SIMV, MANUAL, PEEP, CPAP/SPONT
(standard)
PCV, PSV, BI-LEVEL, S,T, S/T (optional)
 
Parameters
●Tidal volume: 20~2000ML
●Ventilation volume per minute: 0L~20L
●Frequency: 1~100/min
●I/E Ratio: 4:1~1:8
●Holding time: 0~6s
●O2 concentration: 21~100% adjustable.
● Pressure limitation: 0.5~8.0KPa
● Safety Pressure ≤12.5KPa
● PEEP: 0~3.0KPa
● CPAP: 0~2.0KPa
● Inspiration trigger sensitivity:
   pressure -2.0KPa (base on PEEP)
   flow: 1~30L/min
● Sign: 1-5 (per 100 times)
 
 
Ventilation monitoring
●Tidal volume,Minute ventilation,Frequency, Airway Pressure, inspiration time, PEEP, FiO2, PCV,PSV
●Waveform of time-airway Pressure.
 
Alarm (Audible and visible reminding)
●No tidal volume, ventilation volume is too high (low) ,
Airway Pressure is too high (low), frequency is too high,
AC Power off , back up battery voltage is too low
 
Technique info
● Gas source: Oxygen, Air
● Working Pressure: 0.4Mpa
● Reserve Condition: Temperature:-10~40℃, Relative humidity: ≤90%
● Working condition: Temperature:5~40 ℃, Relative humidity:≤80%

 